TM 11-6660-266-13
Table 2-6. Preventive Maintenance Checks and Services
Item
Item to be
Procedure
No.
Inspected
Interval
12.
Inspect DCT case and cover to verify that there are no cracks
DCT
Before
and/or tears. Check that strap is securely fastened.
Power Supply
Inspect connectors to verify that:
13.
Before
Insert is not cracked or broken.
Unit
Contacts are not bent, broken, or missing.
Connector bodies are not damaged and are free of foreign
material.
Connectors are securely mounted.
All surfaces are free of corrosion.
14.
Power Supply
Check switches for:
Before
Secure mounting.
Unit
Proper operation without binding.
Power Supply
Check circuit breakers for:
15.
Before
Secure mounting.
Unit
Proper operation without binding.
Check indicators for:
16.
Power Supply
Before
Secure Mounting.
Unit
Cracked or broken lens.
Inspect exterior of PSU to verify that:
17.
Power Supply
Before
There is no loose, broken, or missing mounting hardware.
Unit
All surfaces are free of dirt, dust, and grease; are free of
corrosion, dents, and scratches.
Inspect connectors to verity that:
Printer
18.
Before
Insert is not cracked or broken.
Contacts are not bent, broken, or missing.
Connector bodies are not damaged and are free of foreign
material.
Connectors are securely mounted.
AU surfaces are free of corrosion.
Check cartridge for secure mounting in carriage and that it has
Printer
19.
Before
adequate ink supply.
Check carriage for freedom of travel.
Printer
20.
Before
Check blotter pad for secure mounting in blotter pad clip.
Printer
21.
Before
Check bail arm rollers for cleanliness and operation without
Printer
22.
Before
binding.
Check platen for cleanliness and operation without binding.
Printer
23.
Before
2-17