TM 75053
AN/TMQ5( )
1. NOMENCLATURE: Recorder, Radiosonde AN/TMQ5,
Dimensions _ _ _ _ _ _ _ _ 33 7/8in. high, 22 7/8 in.
AN/TMQ5A, AN/TMQ5B, AN/TMQ5C.
wide, 17 3/8 in. deep.
Ambient temperature range _ _ _ _ 40 F. to + 125 F.
2. TYPE CLASSIFICATION: C & T.
7. MAJOR COMPONENTS:
3. SECURITY REQUIREMENTS: Unclassified.
Control Panel C834/TMQ5.
Signal Data Converter CV146/TMQ5.
4. PRIMARY USE OR CONCEPT OF EMPLOYMENT:
Power Supply PP968/TMQ5.
Converts audiofrequency signals representing meteorolog-
ical data into graphic form.
8. SET, SYSTEM, FACILITY, AND CONFIGURATION
5. BRIEF FUNCTIONAL DESCRIPTION: Recorder, Ra-
APPLICATION:
diosonde AN/TMQ5( ) is an electronic meteorological
This set is used in a system with Radiosonde Sets
instrument which records, in printed form, weather in-
AN/AMT4( ) or AN/AMT12; Rawin Set AN/GMD
formation transmitted by a balloon-borne radiosonde. Sig-
1( ); and Baseline Check Set AN/GMM1( ).
nals radiated from the radiosonde are received by a
Rawin receiver which converts these signals to audio-
9. ADDITIONAL EQUIPMENT REQUIRED AND AUX-
frequency, which are then fed into the recorder and con-
ILIARY EQUIPMENT:
verted to direct current (dc) voltages. The dc voltages
a. Additional Equipment.
excite a servo system which positions a pen in the re-
Power supply required to provide 105 to 125 v; 50 to
corder to draw a graph on calibrated paper. The graph on
60 Hz; single-phase, 225 to 275 w.
the calibrated paper is then evaluated in terms of
b. Auziliary Equipment.
meteorological data, including temperature, pressure, and
Baseline Check Set AN/GMM1( ).
humidity.
TS1348/GMM1A.
6. TECHNICAL CHARACTERISTICS:
10. TOOLS AND TEST EQUIPMENT:
Power requirements _ _ _ _ _ _105 to 125 vac, to 65
a. Tools.
Hz, single-phase,
225 to 275 w.
Tool Kit, Radar and Radio Repairman TK87/U.
Test signal:
Tool Kit, Radar and Radio Repairman TK88/U.
Sine wave _ _ _ _ _ _ _ _ _ 10 to 220 Hz,10 v
Tool Kit, Radar Repairman TK115/U.
Tube Puller TL201.
peak-to-peak min.
Input signal:
b. Test Equipment.
Negative-going pulse or
Frequency Standard TS65C/FMQ1.
sawtooth _ _ _ _ _ _ _ _ 10 to 220 Hz, 10 to 100v
peak-to-peak, 1,000
Test Set, Electron Tube TV7.
to 2,500 s wide.
Test Set, Electron Tube TV2.
Power supply:
Positive _ _ _ _ _ _ _ _ _ _ _ Self-contained, full-
11. REFERENCE DATA AND LITERATURE:
wave, regulated,
TM 11666020410,
+ 300 v.
25, 25P _ _ _ _ _ _ _ _ AN/TMQ5( )
Negative _ _ _ _ _ _ _ _ _ _ Self-contained, full-
TM 112602B _ _ _ _ _ _ _ _ TS65C/FMQ1
wave, regulated,
SB 11647 _ _ _ _ _ _ _ _ TK88/U
175 v.
TM 11662531612,
Signal data converter _ _ _ _ _ _ _ _ Nominally 30 mv dc for
20P, 35, 35P _ _ _ _ _ _ TV2/U
full-scale deflection
TB 11662531612/1 _ _ _ _ _ TV2/U
of pen.
TB 11662527412/1 _ _ _ _ TV7/U
REF ADJUST frequency
TM 11662527412,
range _ _ _ _ _ _ _ _ _ _ _ _ _ 163 to 242 Hz.
25P, 35 _ _ _ _ _ _ _ _ _ _ TV7/U
Chart:
Length _ _ _ _ _ _ _ _ _ _ 120 ft.
12. REPAIR PARTS SUPPORT CAPABILITY: To 1974
Width _ _ _ _ _ _ _ _ _ _ _ 10 11/16 in. overall.
.
Full support.
Vertical axis _ _ _ _ _ _
in. interval.
13. TRAINING REQUIREMENTS:
Horizontal axis _ _ _ _ _ _ _ _ _ 100 equal divisions.
Operator MOS 93E20, 93F20.
Speed _ _ _ __ _ _ _ _ _ _ _ _ _ _ -in.1min for Radio-
Maintenance MOS 35B20, 35D20.
sonde Recorder AN/
14. TYPICAL BASIS OF ISSUE:
TMQ5; - or 1-in./
min for Radiosonde
TOE
Allowance
Recorder AN/TMQ
6186H_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
5A; -, 1-, or 2-in./
6201G _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
min for Radiosonde
6302H _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
Recorder AN/TMQ
6526G _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
5C.
6576G _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
Speed of response . . . . . . .
2-sec max including
6701H _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
penlifting operation.
6716H _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ __
1
Weight . . . . . . . . . . . . . . . .
240 lb.
7100H _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1
46