TM 11-6660-266-13
ENSURE THAT PRIMARY INPUT POWER IS DISCONNECTED FROM
THE MMS PRIOR TO DISASSEMBLY TO PREVENT ELECTRICAL
SHOCK.
NOTE
After disconnecting cables, place protective covers over cable and
equipment connectors. Tighten covers by turning clockwise.
a. Disconnect primary input power as follows:
(1) Turn off AC and/or DC power sources.
(2) Disconnect cable W3 from DC power source and Power Supply Unit. Repack cable into case #8
(3) Disconnect cable W1 from AC power source and cable W2. Repair cable into case #8.
(4) Disconnect cable W2 from Power Supply Unit. Repack cable into case #8.
b. Repack 24 VDC Power Supply as follows:
(1) Disconnect cables W6 and W20 from 24 VDC Power Supply, RDF Unit, and Power Supply Unit. Repack
cables into case #9.
(2) Disconnect grounding cable and repack into case #9; remove ground rod.
(3) Repack 24 VDC Power Supply into case #9.
c. Disassemble and repack RDF Unit as follows:
TO PREVENT INJURY TO PERSONNEL, TWO SOLDIERS ARE
REQUIRED TO LIFT AND HANDLE THE MAJOR COMPONENTS OF
THE RDF UNIT.
(1) Disconnect cables W18 and W19 from RDF Unit and MARWIN Processor. Repack cables into case #9.
(2) Disconnect cable W10 from RDF Unit and CDU. Repack cable into case #9 and CDU into case #8.
(3) Disconnect two RDF Unit cables between the elevation unit and azimuth unit. Repack cables into case #2.
(4) Remove telescope and repack into case #1.
(5) Remove antenna dish and repack into case #1.
(6) Remove elevation unit and repack into case #2.
(7) Remove azimuth unit and repack into case #3.
2-49