TM 11-6660-266-13
2-64. RDF Sounding. In the procedures below, unless otherwise specified, all references in parentheses refer
to Section 4 of TM 11-6660-280-10. Section 4 contains step by step procedures for operation of the MARWIN
Processor in the RDF mode.
To operate the AN/TMQ-38 in RDF mode, proceed as follows:
a. Verify RDF alignment (TM 11-6660-281-12, para 3-2).
b. Select Preflight Sequence (para 1.2).
ENSURE SAFETY PRECAUTIONS ARE OBSERVED WHILE
ACTIVATING SONDE BATTERY AND HANDLING SENSOR PROBE.
SENSOR PROBE IS EASILY BROKEN IF BENT TO SHARPLY. IF
PROBE IS BROKEN, ME SONDE IS RENDERED USELESS.
c. Activate sonde (para 2.1).
d. Tune RDF receiver (TM 11-6660-281-12, para 3-3.2).
e. Input current station location (para 1.2.6).
NOTE
Enter station altitude in meters.
f. Input "Front dir ()".
NOTE
This step is not shown in TM 11-6660-280-10. Enter true bearing of RDF
h. Enter surface observations (para 1.7).
NOTES
l Current PTU data information can be obtained from activated sonde
(para 1.6).
l Wind speed is entered in meters per second (m/s). Refer to Table 2-7
or conversion of knots to m/s.
i. Launch balloon (para 1.6 and TM 11-6668-281-12, para 3-3.4).
NOTE
Insure "RELEASE" prompt is displayed before launching balloon.
2-46