TM 11-6660-200-14
4-28.
POWER CABLE REPLACEMENT.
NOTE
On some models, power cable comes either connected directly to terminal board TB201 or connected to plug
P401 for connection to jack J401. Both procedures are covered here.
PREPARATION OF NEW CABLE
For direct wiring to TB201:
1. Remove 4 inches (10.16 cm) of outer insulation from end of cable.
2. Remove enough insulation from each wire to solder on terminal lug.
NOTE
For correct soldering methods, refer to TB SIG 222.
3. Solder a terminal lug to both wires.
For connection to J401:
1. Remove 1 inch (2.54 cm) of outer insulation from end of cable.
2. Remove enough insulation from each wire to solder to connector pins.
WARNING
Unplug power cable from power source before attempting replacement procedures.
4-39