(d) Position Power Supply Unit on work surface so that front panel is facing forward.
e. Install interconnect cables W5, W7, W8, W9, and W11 as follows:
(1) Remove cables W5, W7, W8, W9, and W11 from case #8.
(2) Connect DCT Adaptor Cable as follows:
(a) Remove protective covers from connectors W11P1 and W11P3.
(b) Remove protective cover from DCT RS-232C interface connector J1.
(c) Connect W11P1 to DCT RS-232C interface connector J1 by aligning blue dots on connectors.
(d) Connect W11P3 to COMSEC/Radio input connector.
(3) Connect DCT to MARWIN Processor as follows:
(a) Remove protective covers from both connectors on W5 and from W11P2.
(b) Connect W5P2 to W11P2.
(c) Connect W5P1 to MARWIN Processor S1 connector.
(4) Connect DCT to Power Supply Unit as follows:
(a) Remove protective covers from both connection on W9.
(b) Conned W9P1 to DCT power adapter connector P1.
(c) Remove protective cover from Power Supply Unit DCT connector J3.
(d) Connect W9P2 to Power Supply Unit DCT connector J3.
(5) Connect MARWIN Processor to Power Supply Unit as follows:
(a) Connect W7P2 to MARWIN Processor 11OV/22OV connector.
(b) Remove protective covers from Power Supply Unit PROCESSOR AC connector J4 and PROCESSOR
DC connector J5.
(c) Remove protective cover from connector W7P1.
(d) Conned W7P1 to Power Supply Unit PROCESSOR AC connector J4.
(e) Remove protective covers from both connectors on W8.
(f) Conned W8P2 to MARWIN Processor DC IN/OUT connector.
(g) Connect W8P1 to Power Supply Unit PROCESSOR DC connector J5.
2-26