TM 11-6660-200-14
4-8.
FLEXIBLE INTERCONNECTION CABLE TO CONNECTOR HOUSING INSTALLATION
NOTE
For T-420/GMQ-11 and T-420B/GMQ-11, perform step 1. For T-420A/GMQ-11, per-
form step 2.
1. Remove four screws (1) and lock washers (2), and remove connector housing cover (3) and gasket (4). Go to step
3.
2. Tilt hinged connector housing cover (5) upward and remove gasket (4).
3. Remove two screws (6) and lock washers (7).
4. Remove connector J1 (8) from connector housing.
5. Remove 12 inches (30.48 cm) of outer insulation from cable (9).
6. Remove enough insulation from each wire to solder to connector J1 (8).
7. Put prepared end of cable (9) into bottom of lower mast section (10).
8. Push cable (9) up through lower mast section (10) and out opening on top of connector housing (11).
9. Loosen screw (12) on connector J1 (8) and separate case (13) from retainer (14).
NOTE
For correct soldering methods, refer to TB SIG 222.
10.
Solder wires from cable (9) to proper terminals on connector J1 (8) as shown in following table.
4-9