TM 11-6660-200-14
4-8.
1.
2.
Aline setscrew hole (3) with flat surface on generator hub (2).
3.
Install setscrew (4) and tighten.
4.
Install and tighten other setscrew (5).
4-9
INDICATOR ASSEMBLY.
INDICATOR CABLE CONNECTION, ID-373/GMQ-11 OR ID-373B/GMQ-11
NOTE
Steps given are for models where interconnection cables are hard wired directly to
TB201 inside indicator when being prepared for use.
1.
Remove 3 inches of outer insulation from cable end.
2
Remove enough insulation from wires to solder on terminal ends.
NOTE
For correct soldering methods, refer to TB SIG 222.
3.
Solder a terminal lug to each wire of cable end.
4-12