TM 11-6660-200-14
5-12.
WINDSPEED GENERATOR FILTER FL1 OR CAPACITOR C1 REPLACEMENT. (CONT)
REMOVAL
1.
Remove two screws (1), flat washers (2), lockwashers (3), nuts (4), and insulator (5).
2.
NOTE
For correct soldering methods, refer to TB SIG 222.
3.
Using soldering iron, unsolder two white wires (9) and two black wires (10).
4.
Remove four screws (11), lockwashers (12), gasket (13), cover plate (14), and
retainer (15).
5.
Remove filter (16) from generator (17).
INSTALLATION
1.
Place filter (16) bracket on generator (17).
2.
Install retainer (15), gasket (13), and cover plate (14).
3.
NOTE
For correct soldering methods, refer to TB SIG 222.
4.
Using soldering iron, solder two white wires (9) to lug (18) and two black wires (10) to
lug (19).
5.
Install generator holder (8) on generator (17).
6.
7.
Place insulator (5) and brush assembly (20) on bracket (21).
8.
Install two screws (1), flat washers (2), lockwashers (3), and nuts (4).
FOLLOW-ON MAINTENANCE: Install windspeed generator G1 (para 5-10).
5-15