5-15.
TRANSMITTER CONNECTOR PLUG REPLACEMENT. (CONT)
CAUTION
Do not lift transmitter by tail or impeller; lift transmitter by center section only.
2.
3.
4.
Remove screw (7) and lockwasher (8), and separate case (9) from retainer (10).
NOTE
For correct soldering methods, refer to TB SIG 222.
5.
Using soldering iron, unsolder wires from connector pins (11) one at a time, and resolder to
replacement connector pins.
INSTALLATION OF P1 CONNECTOR
1.
Assemble case (9) and retainer (10), and install screw (7) and lockwasher (8).
2.
Install connector into transmitter (3), alining notch (12) with pin inside transmitter.
3.
4.
Install gasket (13) on connector housing (4).
CAUTION
Do not lift transmitter by tail or impeller; lift transmitter by center section only.
5.
Install transmitter (3) on connector housing (4), alining pin (14) with hole (15) and push into
place.
6.
FOLLOW-ON MAINTENANCE: Set support assembly upright (para 4-12).
5-19