TM 11-6660-266-13
(4) Install antenna dish (1) as follows:
(a) Remove antenna dish from case #1.
(b) Lift dish, taking care not to bump into or
otherwise damage dipole-scanner tube (19) and
end plate, slide dish carefully along dipole
scanner tube, ensuring that large and small
holes on dish base align with large (20) and
small pins of elevation unit respectively. Secure
dish with 2 hook latches (21) on elevation unit.
(5) Install telescope (22) as follows:
(a) Remove telescope from case #1.
(b) With bubble level (23) at top, position
telescope on alignment device (24) mounting
rail on elevation unit. Secure with 2 thumb
screws (25).
(6) Recheck 2 linear bubble levels on top of
vertical column base and if necessary, readjust
level by repeating step (2)(d).
(7) Install cables as follows:
(a) Remove cables, PNs 700-5-23-32-342 and
700-5-23-32-343, from case #2.
(b) Remove protective covers from RDF Unit
connectors P11 and J7.
(c) Connect receiver cable (26) PN 700-5-23-
32-342, as follows: P1 to receiver connector
P11 and P2 to vertical column connector J7.
(d) Remove protective covers from RDF Unit
connectors P10 and J6.
(e) Connect elevation drive cable (27) PN 700-
5-23-32-343, as follows: P1 to elevation drive
connector P10 and P2 to vertical column
connector J6.
(f) Remove CDU from case #6 and cable W10
from case #3.
(g) Remove protective covers from RDF
connector J2 and both connectors on W10.
(h) Conned W10P1 to CDU connector.
(i) Connect W10P2 to RDF connector J2.
2-36